[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"skill:01M6AF6SZKJ18P369M9HY8TK0Z":3,"skill-same:01M6AF6SZKJ18P369M9HY8TK0Z":118},{"skillNo":4,"name":5,"nameZh":6,"description":7,"descriptionZh":8,"repositoryFullName":9,"ownerLogin":10,"ownerAvatarUrl":11,"ownerAccountNo":12,"ownerDisplayName":13,"repositoryNo":14,"starsCount":15,"licenseSpdxId":16,"licenseFileUrl":17,"sourceHtmlUrl":18,"categories":19,"keywords":30,"publishedAt":51,"linkOnly":52,"markdownContent":53,"markdownBody":54,"frontMatter":55,"refName":73,"commitSha":74,"skillDirectory":75,"forksCount":76,"repositoryHtmlUrl":77,"repositoryHomepageUrl":78,"ownerHtmlUrl":79,"ownerBlogUrl":80,"ownerDescription":81,"updatedAt":82,"install":83,"resources":96},"01M6AF6SZKJ18P369M9HY8TK0Z","implementing-iec-62443-security-zones","IEC 62443 工业安全区实施","Designs security zones and conduits for industrial control systems (IACS) per IEC 62443-3-2 — risk-based zone partitioning, Security Level target (SL-T) assignment, conduit controls, and firewall microsegmentation validated against the Purdue Reference Model. Use when designing OT network zones for a new facility, retrofitting zones into a flat OT network, or upgrading VLAN-only segmentation for IEC 62443-3-2 compliance.","根据 IEC 62443-3-2 为工业控制系统（IACS）设计安全区和管道——基于风险的区域划分、安全等级目标（SL-T）分配、管道控制和防火墙微隔离，并根据普渡参考模型（Purdue Reference Model）进行验证。适用于为新设施设计 OT 网络区域、将区域改造到扁平 OT 网络中，或升级仅基于 VLAN 的分区以满足 IEC 62443-3-2 合规性。","mukul975\u002FAnthropic-Cybersecurity-Skills","mukul975","https:\u002F\u002Favatars.githubusercontent.com\u002Fu\u002F42860185?v=4","01M6ADEQR8T5M4EEG6C67BQCWF","Mahipal","01M6ADJPMYWG1E5GM1FWBE3128",36146,"Apache-2.0",null,"https:\u002F\u002Fgithub.com\u002Fmukul975\u002FAnthropic-Cybersecurity-Skills\u002Fblob\u002Fmain\u002Fskills\u002Fimplementing-iec-62443-security-zones\u002FSKILL.md",[20,25],{"categoryNo":21,"categoryName":22,"taxonomyType":23,"taxonomyTypeDesc":24},"01M8BR4MYFKGCC4WCWVJ50KJ2C","安全工程师","PROFESSION","适用职业",{"categoryNo":26,"categoryName":27,"taxonomyType":28,"taxonomyTypeDesc":29},"01M8C89HE9N5P9F4ZKF1S850TS","网络安全设备配置与管理","SCENARIO","使用场景",[31,32,33,34,35,36,37,38,39,40,41,42,43,44,45,46,47,48,49,50],"implementing iec 62443 security zones","security","scada","zones-conduits","segmentation","risk-based","risk","t1059","t1078","iec62443","industrial-control","ics","ot-security","firewall","vlan","microsegmentation","network","compliance","pr","cybersecurity","2026-11-10 10:12:30",false,"---\nname: implementing-iec-62443-security-zones\ndescription: 'Designs security zones and conduits for industrial control systems\n  (IACS) per IEC 62443-3-2 — risk-based zone partitioning, Security Level target\n  (SL-T) assignment, conduit controls, and firewall microsegmentation validated\n  against the Purdue Reference Model. Use when designing OT network zones for a\n  new facility, retrofitting zones into a flat OT network, or upgrading VLAN-only\n  segmentation for IEC 62443-3-2 compliance.\n\n  '\ndomain: cybersecurity\nsubdomain: ot-ics-security\ntags:\n- ot-security\n- ics\n- scada\n- industrial-control\n- iec62443\n- network-segmentation\n- zones-conduits\nversion: 1.0.0\nauthor: mahipal\nlicense: Apache-2.0\nnist_csf:\n- PR.IR-01\n- DE.CM-01\n- ID.AM-05\n- GV.OC-02\nmitre_attack:\n- T1078\n- T1190\n- T1059\n- T0816\n- T0836\n---\n\n# Implementing IEC 62443 Security Zones\n\n## When to Use\n\n- When designing a greenfield OT network architecture for a new industrial facility\n- When retrofitting security zones into an existing flat OT network after an assessment finding\n- When implementing network segmentation to comply with IEC 62443-3-2 certification requirements\n- When upgrading from basic VLAN segmentation to policy-enforced zone\u002Fconduit architecture\n- When an IT\u002FOT convergence project requires defining security boundaries between enterprise and operational networks\n\n**Do not use** for IT-only network segmentation (see implementing-network-microsegmentation), for cloud-native workload segmentation (see securing-kubernetes-on-cloud), or for physical security zone design without a cyber component.\n\n## Prerequisites\n\n- Completed OT network security assessment with asset inventory and traffic flow analysis\n- Understanding of IEC 62443-3-2 zone\u002Fconduit design process and the Purdue Reference Model\n- Industrial firewalls capable of deep packet inspection for OT protocols (Palo Alto with OT Security, Fortinet OT, Cisco ISA-3000)\n- Network switches supporting VLANs, 802.1Q trunking, and port security\n- Approval from operations management for network architecture changes during maintenance windows\n\n## Workflow\n\n### Step 1: Perform Zone Partitioning Based on Risk Assessment\n\nPartition the IACS into zones based on functional requirements, security requirements, criticality, and consequence of compromise. Each zone contains assets with common security requirements.\n\n```yaml\n# IEC 62443-3-2 Zone Definition Document\nfacility: \"Petrochemical Refinery - Unit 3\"\nassessment_date: \"2026-02-23\"\nstandard: \"IEC 62443-3-2:2020\"\n\nzones:\n  - zone_id: \"Z1-SIS\"\n    name: \"Safety Instrumented Systems\"\n    purdue_level: 1\n    security_level_target: \"SL 3\"\n    criticality: \"Safety Critical\"\n    assets:\n      - \"Triconex 3008 Safety Controller (SIS-01)\"\n      - \"Triconex 3008 Safety Controller (SIS-02)\"\n      - \"SIS Engineering Workstation\"\n    security_requirements:\n      - \"Physically isolated from all other zones (air-gapped)\"\n      - \"Dedicated engineering workstation with removable media controls\"\n      - \"No remote access permitted under any circumstances\"\n      - \"Change management requires dual authorization\"\n    allowed_conduits: []  # No network conduits - fully air-gapped\n\n  - zone_id: \"Z2-BPCS\"\n    name: \"Basic Process Control System\"\n    purdue_level: \"1-2\"\n    security_level_target: \"SL 2\"\n    criticality: \"High\"\n    assets:\n      - \"Allen-Bradley ControlLogix PLCs (PLC-01 through PLC-12)\"\n      - \"Rockwell FactoryTalk View HMIs (HMI-01 through HMI-06)\"\n      - \"Engineering Workstation (EWS-01)\"\n    security_requirements:\n      - \"Industrial firewall at zone boundary with protocol inspection\"\n      - \"Read-only access from Level 3 for data acquisition\"\n      - \"Write access restricted to engineering workstation subnet\"\n      - \"USB ports disabled on HMIs\"\n    allowed_conduits: [\"C1-BPCS-OPS\"]\n\n  - zone_id: \"Z3-OPS\"\n    name: \"Site Operations\"\n    purdue_level: 3\n    security_level_target: \"SL 2\"\n    criticality: \"Medium\"\n    assets:\n      - \"OSIsoft PI Historian (HIST-01)\"\n      - \"OPC UA Server (OPC-01)\"\n      - \"MES Application Server (MES-01)\"\n      - \"Alarm Management Server (ALM-01)\"\n    security_requirements:\n      - \"Firewall between operations and control zones\"\n      - \"Firewall between operations and DMZ\"\n      - \"No direct internet access\"\n      - \"Antivirus with OT-approved signatures\"\n    allowed_conduits: [\"C1-BPCS-OPS\", \"C2-OPS-DMZ\"]\n\n  - zone_id: \"Z4-DMZ\"\n    name: \"Industrial Demilitarized Zone\"\n    purdue_level: 3.5\n    security_level_target: \"SL 2\"\n    criticality: \"Medium\"\n    assets:\n      - \"PI-to-PI Interface (DMZ-HIST-01)\"\n      - \"Patch Management Server (DMZ-WSUS-01)\"\n      - \"Remote Access Jump Server (DMZ-JUMP-01)\"\n      - \"Data Diode - Waterfall Security (DMZ-DD-01)\"\n    security_requirements:\n      - \"Dual-homed firewalls on both sides\"\n      - \"No direct traffic traversal - all connections terminate in DMZ\"\n      - \"Data diode for unidirectional historian replication\"\n      - \"Jump server with MFA for remote access\"\n    allowed_conduits: [\"C2-OPS-DMZ\", \"C3-DMZ-ENT\"]\n\n  - zone_id: \"Z5-ENT\"\n    name: \"Enterprise Network\"\n    purdue_level: 4\n    security_level_target: \"SL 1\"\n    criticality: \"Low (from OT perspective)\"\n    assets:\n      - \"Corporate systems accessing OT data\"\n    security_requirements:\n      - \"Firewall between enterprise and DMZ\"\n      - \"No direct access to any OT zone below DMZ\"\n    allowed_conduits: [\"C3-DMZ-ENT\"]\n\nconduits:\n  - conduit_id: \"C1-BPCS-OPS\"\n    name: \"Control-to-Operations Conduit\"\n    connects: [\"Z2-BPCS\", \"Z3-OPS\"]\n    security_level: \"SL 2\"\n    protocols_allowed:\n      - protocol: \"OPC UA\"\n        port: 4840\n        direction: \"Z2 -> Z3 (read only)\"\n        security_mode: \"SignAndEncrypt\"\n      - protocol: \"Modbus\u002FTCP\"\n        port: 502\n        direction: \"Z3 -> Z2 (read only, FC 3\u002F4 only)\"\n        security_mode: \"Firewall-enforced function code filtering\"\n    controls:\n      - \"Industrial firewall with OT protocol DPI\"\n      - \"Allowlisted source\u002Fdestination IP pairs\"\n      - \"Function code filtering (block all write operations from L3)\"\n      - \"Connection rate limiting\"\n\n  - conduit_id: \"C2-OPS-DMZ\"\n    name: \"Operations-to-DMZ Conduit\"\n    connects: [\"Z3-OPS\", \"Z4-DMZ\"]\n    security_level: \"SL 2\"\n    protocols_allowed:\n      - protocol: \"PI-to-PI\"\n        port: 5450\n        direction: \"Z3 -> Z4 (unidirectional via data diode)\"\n      - protocol: \"HTTPS\"\n        port: 443\n        direction: \"Z4 -> Z3 (patch downloads only)\"\n    controls:\n      - \"Data diode for historian replication (Waterfall Security)\"\n      - \"Firewall with application-layer inspection\"\n      - \"Patch server pulls only from approved vendor repositories\"\n\n  - conduit_id: \"C3-DMZ-ENT\"\n    name: \"DMZ-to-Enterprise Conduit\"\n    connects: [\"Z4-DMZ\", \"Z5-ENT\"]\n    security_level: \"SL 1\"\n    protocols_allowed:\n      - protocol: \"HTTPS\"\n        port: 443\n        direction: \"Z5 -> Z4 (historian read, remote access portal)\"\n      - protocol: \"RDP\"\n        port: 3389\n        direction: \"Z5 -> Z4 (jump server with MFA)\"\n    controls:\n      - \"Next-gen firewall with SSL inspection\"\n      - \"MFA required for all remote access sessions\"\n      - \"Session recording on jump server\"\n```\n\n### Step 2: Configure Industrial Firewalls for Zone Boundaries\n\nDeploy and configure industrial-grade firewalls at each zone boundary with OT protocol-aware deep packet inspection.\n\n```bash\n# Cisco ISA-3000 Industrial Firewall Configuration\n# Conduit C1: BPCS (Zone 2) \u003C-> Operations (Zone 3)\n\n# Define zone interfaces\ninterface GigabitEthernet1\u002F1\n  nameif zone-bpcs\n  security-level 90\n  ip address 10.20.1.1 255.255.0.0\n\ninterface GigabitEthernet1\u002F2\n  nameif zone-ops\n  security-level 70\n  ip address 10.30.1.1 255.255.0.0\n\n# OPC UA from BPCS to Operations (read-only data flow)\naccess-list BPCS-to-OPS extended permit tcp 10.20.0.0 255.255.0.0 host 10.30.1.50 eq 4840\n# Modbus read from Operations historian to PLCs (FC 3,4 only)\naccess-list OPS-to-BPCS extended permit tcp host 10.30.1.50 10.20.0.0 255.255.0.0 eq 502\n\n# Deny all other traffic between zones\naccess-list BPCS-to-OPS extended deny ip any any log\naccess-list OPS-to-BPCS extended deny ip any any log\n\n# Apply access lists\naccess-group BPCS-to-OPS in interface zone-bpcs\naccess-group OPS-to-BPCS in interface zone-ops\n\n# Enable Modbus protocol inspection with function code filtering\npolicy-map type inspect modbus MODBUS-INSPECT\n  parameters\n    # Allow read operations only from Operations zone\n    match func-code read-coils\n    match func-code read-discrete-inputs\n    match func-code read-holding-registers\n    match func-code read-input-registers\n    # Block all write function codes\n    match func-code force-single-coil  action drop log\n    match func-code preset-single-register  action drop log\n    match func-code force-multiple-coils  action drop log\n    match func-code preset-multiple-registers  action drop log\n\n# Apply to service policy\npolicy-map global_policy\n  class inspection_default\n    inspect modbus MODBUS-INSPECT\n\n# Logging to OT SIEM\nlogging host zone-ops 10.30.1.60\nlogging trap informational\nlogging enable\n```\n\n### Step 3: Implement VLAN Segmentation at Switch Level\n\nConfigure network switches to enforce zone boundaries at Layer 2, preventing broadcast domain overlap between Purdue levels.\n\n```bash\n# Cisco Industrial Ethernet Switch Configuration\n# Zone-based VLAN assignment\n\n# VLAN definitions aligned with zones\nvlan 10\n  name Z1-SIS-Safety\nvlan 20\n  name Z2-BPCS-Control\nvlan 30\n  name Z3-OPS-Operations\nvlan 35\n  name Z4-DMZ\nvlan 40\n  name Z5-Enterprise\n\n# PLC ports - Zone 2 BPCS\ninterface range GigabitEthernet1\u002F0\u002F1-12\n  description PLC connections - Zone 2\n  switchport mode access\n  switchport access vlan 20\n  switchport port-security\n  switchport port-security maximum 1\n  switchport port-security mac-address sticky\n  switchport port-security violation shutdown\n  spanning-tree portfast\n  spanning-tree bpduguard enable\n  no cdp enable\n  no lldp transmit\n\n# HMI ports - Zone 2 BPCS\ninterface range GigabitEthernet1\u002F0\u002F13-18\n  description HMI connections - Zone 2\n  switchport mode access\n  switchport access vlan 20\n  switchport port-security\n  switchport port-security maximum 1\n  switchport port-security mac-address sticky\n  switchport port-security violation restrict\n  spanning-tree portfast\n\n# Trunk to industrial firewall\ninterface GigabitEthernet1\u002F0\u002F24\n  description Trunk to ISA-3000 Firewall\n  switchport mode trunk\n  switchport trunk allowed vlan 20,30,35\n  switchport trunk native vlan 999\n\n# Disable unused ports\ninterface range GigabitEthernet1\u002F0\u002F19-23\n  shutdown\n  switchport access vlan 999\n```\n\n### Step 4: Deploy Data Diode for Unidirectional Historian Replication\n\nInstall a hardware-enforced data diode between the operations zone and DMZ to ensure unidirectional data flow from OT to IT. Data diodes physically prevent any data from flowing back into the OT network.\n\n```python\n#!\u002Fusr\u002Fbin\u002Fenv python3\n\"\"\"Data Diode Configuration Validator.\n\nValidates that historian replication across the data diode\n(Waterfall Security, Owl Cyber Defense, or Siemens) is\nfunctioning correctly with unidirectional enforcement.\n\"\"\"\n\nimport socket\nimport struct\nimport time\nimport json\nfrom datetime import datetime\n\n\nclass DataDiodeValidator:\n    \"\"\"Validates data diode unidirectional enforcement.\"\"\"\n\n    def __init__(self, diode_tx_ip, diode_rx_ip, historian_port=5450):\n        self.tx_ip = diode_tx_ip  # OT side (transmit)\n        self.rx_ip = diode_rx_ip  # IT\u002FDMZ side (receive)\n        self.port = historian_port\n        self.results = []\n\n    def test_forward_flow(self):\n        \"\"\"Verify data flows from OT (TX) to DMZ (RX) through diode.\"\"\"\n        test_payload = f\"DIODE_TEST_{datetime.now().isoformat()}\"\n\n        try:\n            # Send test data to TX interface\n            sock = socket.socket(socket.AF_INET, socket.SOCK_DGRAM)\n            sock.settimeout(5)\n            sock.sendto(test_payload.encode(), (self.tx_ip, self.port))\n            sock.close()\n\n            self.results.append({\n                \"test\": \"forward_flow\",\n                \"status\": \"PASS\",\n                \"detail\": f\"Data sent to TX interface {self.tx_ip}:{self.port}\",\n            })\n        except Exception as e:\n            self.results.append({\n                \"test\": \"forward_flow\",\n                \"status\": \"FAIL\",\n                \"detail\": f\"Cannot reach TX interface: {e}\",\n            })\n\n    def test_reverse_flow_blocked(self):\n        \"\"\"Verify reverse flow (DMZ to OT) is physically blocked by diode.\"\"\"\n        try:\n            sock = socket.socket(socket.AF_INET, socket.SOCK_STREAM)\n            sock.settimeout(3)\n            result = sock.connect_ex((self.tx_ip, self.port))\n            sock.close()\n\n            if result != 0:\n                self.results.append({\n                    \"test\": \"reverse_flow_blocked\",\n                    \"status\": \"PASS\",\n                    \"detail\": \"Reverse connection to OT side correctly rejected\",\n                })\n            else:\n                self.results.append({\n                    \"test\": \"reverse_flow_blocked\",\n                    \"status\": \"CRITICAL_FAIL\",\n                    \"detail\": \"REVERSE FLOW POSSIBLE - Data diode bypass detected!\",\n                })\n        except (socket.timeout, ConnectionRefusedError):\n            self.results.append({\n                \"test\": \"reverse_flow_blocked\",\n                \"status\": \"PASS\",\n                \"detail\": \"Reverse connection timed out (expected with hardware diode)\",\n            })\n\n    def test_historian_replication_latency(self):\n        \"\"\"Measure replication latency across the data diode.\"\"\"\n        try:\n            sock = socket.socket(socket.AF_INET, socket.SOCK_STREAM)\n            sock.settimeout(10)\n            start = time.time()\n            sock.connect((self.rx_ip, self.port))\n            latency = (time.time() - start) * 1000\n            sock.close()\n\n            status = \"PASS\" if latency \u003C 1000 else \"WARN\"\n            self.results.append({\n                \"test\": \"replication_latency\",\n                \"status\": status,\n                \"detail\": f\"Replication endpoint latency: {latency:.1f}ms\",\n            })\n        except Exception as e:\n            self.results.append({\n                \"test\": \"replication_latency\",\n                \"status\": \"FAIL\",\n                \"detail\": f\"Cannot reach RX historian: {e}\",\n            })\n\n    def run_all_tests(self):\n        \"\"\"Run complete data diode validation suite.\"\"\"\n        print(\"=\" * 60)\n        print(\"DATA DIODE VALIDATION REPORT\")\n        print(\"=\" * 60)\n\n        self.test_forward_flow()\n        self.test_reverse_flow_blocked()\n        self.test_historian_replication_latency()\n\n        for r in self.results:\n            status_icon = \"+\" if r[\"status\"] == \"PASS\" else \"-\"\n            print(f\"  [{status_icon}] {r['test']}: {r['status']}\")\n            print(f\"      {r['detail']}\")\n\n        return self.results\n\n\nif __name__ == \"__main__\":\n    validator = DataDiodeValidator(\n        diode_tx_ip=\"10.30.1.100\",   # Operations zone TX\n        diode_rx_ip=\"172.16.1.100\",  # DMZ zone RX\n    )\n    validator.run_all_tests()\n```\n\n### Step 5: Validate Zone Architecture\n\nAfter implementation, validate the zone architecture by verifying that only authorized conduit traffic passes between zones and that all prohibited cross-zone paths are blocked.\n\n```bash\n# Validation test from Enterprise zone - should be blocked from reaching BPCS\nnmap -sT -p 502,44818,102,4840 10.20.0.0\u002F16 --reason\n# Expected: All ports filtered\u002Fclosed\n\n# Validation test from Operations zone - read-only Modbus should work\npython3 -c \"\nfrom pymodbus.client import ModbusTcpClient\nclient = ModbusTcpClient('10.20.1.10', port=502)\nclient.connect()\n# Read should succeed\nresult = client.read_holding_registers(0, 10, slave=1)\nprint(f'Read test: {\\\"PASS\\\" if not result.isError() else \\\"FAIL\\\"}')\n# Write should be blocked by firewall\nresult = client.write_register(0, 100, slave=1)\nprint(f'Write blocked: {\\\"PASS\\\" if result.isError() else \\\"FAIL - WRITE PERMITTED!\\\"}')\nclient.close()\n\"\n\n# Verify data diode blocks reverse traffic\nping -c 3 10.30.1.100  # From DMZ to OT - should timeout\n# Expected: 100% packet loss (hardware diode blocks ICMP)\n```\n\n## Key Concepts\n\n| Term | Definition |\n|------|------------|\n| Security Zone | A grouping of logical or physical assets that share common security requirements, as defined by IEC 62443-3-2 |\n| Conduit | A logical grouping of communication channels connecting two or more zones, subject to common security policies |\n| Security Level Target (SL-T) | The desired security level for a zone, ranging from SL 1 (casual violation) to SL 4 (state-sponsored attack) |\n| Data Diode | Hardware-enforced unidirectional network gateway that physically prevents data from flowing in the reverse direction |\n| Microsegmentation | Granular network segmentation at the device level, managing communication device-by-device based on roles and functions |\n| Deep Packet Inspection (DPI) | Firewall capability to inspect industrial protocol payloads (Modbus function codes, OPC UA service calls) beyond Layer 4 |\n| Defense in Depth | Layered security approach where multiple security controls protect assets at different levels of the architecture |\n\n## Tools & Systems\n\n- **Cisco ISA-3000**: Industrial security appliance providing OT-aware firewall, IPS, and VPN capabilities with Modbus, DNP3, and EtherNet\u002FIP inspection\n- **Fortinet FortiGate Rugged**: Ruggedized next-gen firewall with OT protocol support for industrial environments\n- **Palo Alto IoT\u002FOT Security**: Cloud-delivered OT security subscription providing device identification and protocol-aware policy enforcement\n- **Waterfall Security Solutions**: Hardware-enforced unidirectional security gateways (data diodes) for OT-to-IT data transfer\n- **Tofino Xenon**: Industrial security appliance providing deep packet inspection for Modbus, OPC, and EtherNet\u002FIP protocols\n\n## Common Scenarios\n\n### Scenario: Migrating Flat OT Network to Zone Architecture\n\n**Context**: A manufacturing plant operates all OT devices on a single VLAN (10.10.0.0\u002F16) with no segmentation between PLCs, HMIs, historians, and the corporate network. An IEC 62443 gap assessment identified this as a critical finding requiring zone implementation.\n\n**Approach**:\n1. Capture complete traffic baseline for 4 weeks using passive monitoring to identify all legitimate communication flows\n2. Classify all assets into Purdue levels and group into logical zones based on function and security requirements\n3. Design VLAN architecture with one VLAN per zone and inter-zone firewall rules based on observed legitimate traffic\n4. Deploy industrial firewalls at zone boundaries with initial \"monitor only\" mode (log but do not block)\n5. Analyze firewall logs for 2 weeks to identify any legitimate traffic that would be blocked\n6. Switch firewalls to enforcement mode during a scheduled maintenance window\n7. Validate that all process control communications function correctly post-segmentation\n8. Implement data diode between operations and DMZ for historian replication\n\n**Pitfalls**: Implementing zone firewalls without a complete traffic baseline will break unknown but legitimate communication paths. Scheduling zone cutover during production instead of maintenance windows risks process disruptions. Placing SIS controllers in the same zone as BPCS violates IEC 62443 safety system isolation requirements.\n\n## Output Format\n\n```\nIEC 62443 Zone Implementation Report\n=====================================\nFacility: [Name]\nImplementation Date: YYYY-MM-DD\nStandard: IEC 62443-3-2\u002F3-3\n\nZONE ARCHITECTURE:\n  Zone [ID]: [Name] (SL-T: [1-4])\n    Assets: [count]\n    Conduits: [list]\n    Controls: [firewall type, data diode, etc.]\n\nCONDUIT CONFIGURATION:\n  Conduit [ID]: [Zone A] \u003C-> [Zone B]\n    Protocols: [allowed protocols with direction]\n    Firewall Rules: [count allow \u002F count deny]\n    DPI Enabled: Yes\u002FNo\n\nVALIDATION RESULTS:\n  Cross-zone tests: [pass\u002Ffail count]\n  Prohibited path tests: [all blocked \u002F exceptions]\n  Protocol enforcement: [function code filtering verified]\n```\n","# Implementing IEC 62443 Security Zones\n\n## When to Use\n\n- When designing a greenfield OT network architecture for a new industrial facility\n- When retrofitting security zones into an existing flat OT network after an assessment finding\n- When implementing network segmentation to comply with IEC 62443-3-2 certification requirements\n- When upgrading from basic VLAN segmentation to policy-enforced zone\u002Fconduit architecture\n- When an IT\u002FOT convergence project requires defining security boundaries between enterprise and operational networks\n\n**Do not use** for IT-only network segmentation (see implementing-network-microsegmentation), for cloud-native workload segmentation (see securing-kubernetes-on-cloud), or for physical security zone design without a cyber component.\n\n## Prerequisites\n\n- Completed OT network security assessment with asset inventory and traffic flow analysis\n- Understanding of IEC 62443-3-2 zone\u002Fconduit design process and the Purdue Reference Model\n- Industrial firewalls capable of deep packet inspection for OT protocols (Palo Alto with OT Security, Fortinet OT, Cisco ISA-3000)\n- Network switches supporting VLANs, 802.1Q trunking, and port security\n- Approval from operations management for network architecture changes during maintenance windows\n\n## Workflow\n\n### Step 1: Perform Zone Partitioning Based on Risk Assessment\n\nPartition the IACS into zones based on functional requirements, security requirements, criticality, and consequence of compromise. Each zone contains assets with common security requirements.\n\n```yaml\n# IEC 62443-3-2 Zone Definition Document\nfacility: \"Petrochemical Refinery - Unit 3\"\nassessment_date: \"2026-02-23\"\nstandard: \"IEC 62443-3-2:2020\"\n\nzones:\n  - zone_id: \"Z1-SIS\"\n    name: \"Safety Instrumented Systems\"\n    purdue_level: 1\n    security_level_target: \"SL 3\"\n    criticality: \"Safety Critical\"\n    assets:\n      - \"Triconex 3008 Safety Controller (SIS-01)\"\n      - \"Triconex 3008 Safety Controller (SIS-02)\"\n      - \"SIS Engineering Workstation\"\n    security_requirements:\n      - \"Physically isolated from all other zones (air-gapped)\"\n      - \"Dedicated engineering workstation with removable media controls\"\n      - \"No remote access permitted under any circumstances\"\n      - \"Change management requires dual authorization\"\n    allowed_conduits: []  # No network conduits - fully air-gapped\n\n  - zone_id: \"Z2-BPCS\"\n    name: \"Basic Process Control System\"\n    purdue_level: \"1-2\"\n    security_level_target: \"SL 2\"\n    criticality: \"High\"\n    assets:\n      - \"Allen-Bradley ControlLogix PLCs (PLC-01 through PLC-12)\"\n      - \"Rockwell FactoryTalk View HMIs (HMI-01 through HMI-06)\"\n      - \"Engineering Workstation (EWS-01)\"\n    security_requirements:\n      - \"Industrial firewall at zone boundary with protocol inspection\"\n      - \"Read-only access from Level 3 for data acquisition\"\n      - \"Write access restricted to engineering workstation subnet\"\n      - \"USB ports disabled on HMIs\"\n    allowed_conduits: [\"C1-BPCS-OPS\"]\n\n  - zone_id: \"Z3-OPS\"\n    name: \"Site Operations\"\n    purdue_level: 3\n    security_level_target: \"SL 2\"\n    criticality: \"Medium\"\n    assets:\n      - \"OSIsoft PI Historian (HIST-01)\"\n      - \"OPC UA Server (OPC-01)\"\n      - \"MES Application Server (MES-01)\"\n      - \"Alarm Management Server (ALM-01)\"\n    security_requirements:\n      - \"Firewall between operations and control zones\"\n      - \"Firewall between operations and DMZ\"\n      - \"No direct internet access\"\n      - \"Antivirus with OT-approved signatures\"\n    allowed_conduits: [\"C1-BPCS-OPS\", \"C2-OPS-DMZ\"]\n\n  - zone_id: \"Z4-DMZ\"\n    name: \"Industrial Demilitarized Zone\"\n    purdue_level: 3.5\n    security_level_target: \"SL 2\"\n    criticality: \"Medium\"\n    assets:\n      - \"PI-to-PI Interface (DMZ-HIST-01)\"\n      - \"Patch Management Server (DMZ-WSUS-01)\"\n      - \"Remote Access Jump Server (DMZ-JUMP-01)\"\n      - \"Data Diode - Waterfall Security (DMZ-DD-01)\"\n    security_requirements:\n      - \"Dual-homed firewalls on both sides\"\n      - \"No direct traffic traversal - all connections terminate in DMZ\"\n      - \"Data diode for unidirectional historian replication\"\n      - \"Jump server with MFA for remote access\"\n    allowed_conduits: [\"C2-OPS-DMZ\", \"C3-DMZ-ENT\"]\n\n  - zone_id: \"Z5-ENT\"\n    name: \"Enterprise Network\"\n    purdue_level: 4\n    security_level_target: \"SL 1\"\n    criticality: \"Low (from OT perspective)\"\n    assets:\n      - \"Corporate systems accessing OT data\"\n    security_requirements:\n      - \"Firewall between enterprise and DMZ\"\n      - \"No direct access to any OT zone below DMZ\"\n    allowed_conduits: [\"C3-DMZ-ENT\"]\n\nconduits:\n  - conduit_id: \"C1-BPCS-OPS\"\n    name: \"Control-to-Operations Conduit\"\n    connects: [\"Z2-BPCS\", \"Z3-OPS\"]\n    security_level: \"SL 2\"\n    protocols_allowed:\n      - protocol: \"OPC UA\"\n        port: 4840\n        direction: \"Z2 -> Z3 (read only)\"\n        security_mode: \"SignAndEncrypt\"\n      - protocol: \"Modbus\u002FTCP\"\n        port: 502\n        direction: \"Z3 -> Z2 (read only, FC 3\u002F4 only)\"\n        security_mode: \"Firewall-enforced function code filtering\"\n    controls:\n      - \"Industrial firewall with OT protocol DPI\"\n      - \"Allowlisted source\u002Fdestination IP pairs\"\n      - \"Function code filtering (block all write operations from L3)\"\n      - \"Connection rate limiting\"\n\n  - conduit_id: \"C2-OPS-DMZ\"\n    name: \"Operations-to-DMZ Conduit\"\n    connects: [\"Z3-OPS\", \"Z4-DMZ\"]\n    security_level: \"SL 2\"\n    protocols_allowed:\n      - protocol: \"PI-to-PI\"\n        port: 5450\n        direction: \"Z3 -> Z4 (unidirectional via data diode)\"\n      - protocol: \"HTTPS\"\n        port: 443\n        direction: \"Z4 -> Z3 (patch downloads only)\"\n    controls:\n      - \"Data diode for historian replication (Waterfall Security)\"\n      - \"Firewall with application-layer inspection\"\n      - \"Patch server pulls only from approved vendor repositories\"\n\n  - conduit_id: \"C3-DMZ-ENT\"\n    name: \"DMZ-to-Enterprise Conduit\"\n    connects: [\"Z4-DMZ\", \"Z5-ENT\"]\n    security_level: \"SL 1\"\n    protocols_allowed:\n      - protocol: \"HTTPS\"\n        port: 443\n        direction: \"Z5 -> Z4 (historian read, remote access portal)\"\n      - protocol: \"RDP\"\n        port: 3389\n        direction: \"Z5 -> Z4 (jump server with MFA)\"\n    controls:\n      - \"Next-gen firewall with SSL inspection\"\n      - \"MFA required for all remote access sessions\"\n      - \"Session recording on jump server\"\n```\n\n### Step 2: Configure Industrial Firewalls for Zone Boundaries\n\nDeploy and configure industrial-grade firewalls at each zone boundary with OT protocol-aware deep packet inspection.\n\n```bash\n# Cisco ISA-3000 Industrial Firewall Configuration\n# Conduit C1: BPCS (Zone 2) \u003C-> Operations (Zone 3)\n\n# Define zone interfaces\ninterface GigabitEthernet1\u002F1\n  nameif zone-bpcs\n  security-level 90\n  ip address 10.20.1.1 255.255.0.0\n\ninterface GigabitEthernet1\u002F2\n  nameif zone-ops\n  security-level 70\n  ip address 10.30.1.1 255.255.0.0\n\n# OPC UA from BPCS to Operations (read-only data flow)\naccess-list BPCS-to-OPS extended permit tcp 10.20.0.0 255.255.0.0 host 10.30.1.50 eq 4840\n# Modbus read from Operations historian to PLCs (FC 3,4 only)\naccess-list OPS-to-BPCS extended permit tcp host 10.30.1.50 10.20.0.0 255.255.0.0 eq 502\n\n# Deny all other traffic between zones\naccess-list BPCS-to-OPS extended deny ip any any log\naccess-list OPS-to-BPCS extended deny ip any any log\n\n# Apply access lists\naccess-group BPCS-to-OPS in interface zone-bpcs\naccess-group OPS-to-BPCS in interface zone-ops\n\n# Enable Modbus protocol inspection with function code filtering\npolicy-map type inspect modbus MODBUS-INSPECT\n  parameters\n    # Allow read operations only from Operations zone\n    match func-code read-coils\n    match func-code read-discrete-inputs\n    match func-code read-holding-registers\n    match func-code read-input-registers\n    # Block all write function codes\n    match func-code force-single-coil  action drop log\n    match func-code preset-single-register  action drop log\n    match func-code force-multiple-coils  action drop log\n    match func-code preset-multiple-registers  action drop log\n\n# Apply to service policy\npolicy-map global_policy\n  class inspection_default\n    inspect modbus MODBUS-INSPECT\n\n# Logging to OT SIEM\nlogging host zone-ops 10.30.1.60\nlogging trap informational\nlogging enable\n```\n\n### Step 3: Implement VLAN Segmentation at Switch Level\n\nConfigure network switches to enforce zone boundaries at Layer 2, preventing broadcast domain overlap between Purdue levels.\n\n```bash\n# Cisco Industrial Ethernet Switch Configuration\n# Zone-based VLAN assignment\n\n# VLAN definitions aligned with zones\nvlan 10\n  name Z1-SIS-Safety\nvlan 20\n  name Z2-BPCS-Control\nvlan 30\n  name Z3-OPS-Operations\nvlan 35\n  name Z4-DMZ\nvlan 40\n  name Z5-Enterprise\n\n# PLC ports - Zone 2 BPCS\ninterface range GigabitEthernet1\u002F0\u002F1-12\n  description PLC connections - Zone 2\n  switchport mode access\n  switchport access vlan 20\n  switchport port-security\n  switchport port-security maximum 1\n  switchport port-security mac-address sticky\n  switchport port-security violation shutdown\n  spanning-tree portfast\n  spanning-tree bpduguard enable\n  no cdp enable\n  no lldp transmit\n\n# HMI ports - Zone 2 BPCS\ninterface range GigabitEthernet1\u002F0\u002F13-18\n  description HMI connections - Zone 2\n  switchport mode access\n  switchport access vlan 20\n  switchport port-security\n  switchport port-security maximum 1\n  switchport port-security mac-address sticky\n  switchport port-security violation restrict\n  spanning-tree portfast\n\n# Trunk to industrial firewall\ninterface GigabitEthernet1\u002F0\u002F24\n  description Trunk to ISA-3000 Firewall\n  switchport mode trunk\n  switchport trunk allowed vlan 20,30,35\n  switchport trunk native vlan 999\n\n# Disable unused ports\ninterface range GigabitEthernet1\u002F0\u002F19-23\n  shutdown\n  switchport access vlan 999\n```\n\n### Step 4: Deploy Data Diode for Unidirectional Historian Replication\n\nInstall a hardware-enforced data diode between the operations zone and DMZ to ensure unidirectional data flow from OT to IT. Data diodes physically prevent any data from flowing back into the OT network.\n\n```python\n#!\u002Fusr\u002Fbin\u002Fenv python3\n\"\"\"Data Diode Configuration Validator.\n\nValidates that historian replication across the data diode\n(Waterfall Security, Owl Cyber Defense, or Siemens) is\nfunctioning correctly with unidirectional enforcement.\n\"\"\"\n\nimport socket\nimport struct\nimport time\nimport json\nfrom datetime import datetime\n\n\nclass DataDiodeValidator:\n    \"\"\"Validates data diode unidirectional enforcement.\"\"\"\n\n    def __init__(self, diode_tx_ip, diode_rx_ip, historian_port=5450):\n        self.tx_ip = diode_tx_ip  # OT side (transmit)\n        self.rx_ip = diode_rx_ip  # IT\u002FDMZ side (receive)\n        self.port = historian_port\n        self.results = []\n\n    def test_forward_flow(self):\n        \"\"\"Verify data flows from OT (TX) to DMZ (RX) through diode.\"\"\"\n        test_payload = f\"DIODE_TEST_{datetime.now().isoformat()}\"\n\n        try:\n            # Send test data to TX interface\n            sock = socket.socket(socket.AF_INET, socket.SOCK_DGRAM)\n            sock.settimeout(5)\n            sock.sendto(test_payload.encode(), (self.tx_ip, self.port))\n            sock.close()\n\n            self.results.append({\n                \"test\": \"forward_flow\",\n                \"status\": \"PASS\",\n                \"detail\": f\"Data sent to TX interface {self.tx_ip}:{self.port}\",\n            })\n        except Exception as e:\n            self.results.append({\n                \"test\": \"forward_flow\",\n                \"status\": \"FAIL\",\n                \"detail\": f\"Cannot reach TX interface: {e}\",\n            })\n\n    def test_reverse_flow_blocked(self):\n        \"\"\"Verify reverse flow (DMZ to OT) is physically blocked by diode.\"\"\"\n        try:\n            sock = socket.socket(socket.AF_INET, socket.SOCK_STREAM)\n            sock.settimeout(3)\n            result = sock.connect_ex((self.tx_ip, self.port))\n            sock.close()\n\n            if result != 0:\n                self.results.append({\n                    \"test\": \"reverse_flow_blocked\",\n                    \"status\": \"PASS\",\n                    \"detail\": \"Reverse connection to OT side correctly rejected\",\n                })\n            else:\n                self.results.append({\n                    \"test\": \"reverse_flow_blocked\",\n                    \"status\": \"CRITICAL_FAIL\",\n                    \"detail\": \"REVERSE FLOW POSSIBLE - Data diode bypass detected!\",\n                })\n        except (socket.timeout, ConnectionRefusedError):\n            self.results.append({\n                \"test\": \"reverse_flow_blocked\",\n                \"status\": \"PASS\",\n                \"detail\": \"Reverse connection timed out (expected with hardware diode)\",\n            })\n\n    def test_historian_replication_latency(self):\n        \"\"\"Measure replication latency across the data diode.\"\"\"\n        try:\n            sock = socket.socket(socket.AF_INET, socket.SOCK_STREAM)\n            sock.settimeout(10)\n            start = time.time()\n            sock.connect((self.rx_ip, self.port))\n            latency = (time.time() - start) * 1000\n            sock.close()\n\n            status = \"PASS\" if latency \u003C 1000 else \"WARN\"\n            self.results.append({\n                \"test\": \"replication_latency\",\n                \"status\": status,\n                \"detail\": f\"Replication endpoint latency: {latency:.1f}ms\",\n            })\n        except Exception as e:\n            self.results.append({\n                \"test\": \"replication_latency\",\n                \"status\": \"FAIL\",\n                \"detail\": f\"Cannot reach RX historian: {e}\",\n            })\n\n    def run_all_tests(self):\n        \"\"\"Run complete data diode validation suite.\"\"\"\n        print(\"=\" * 60)\n        print(\"DATA DIODE VALIDATION REPORT\")\n        print(\"=\" * 60)\n\n        self.test_forward_flow()\n        self.test_reverse_flow_blocked()\n        self.test_historian_replication_latency()\n\n        for r in self.results:\n            status_icon = \"+\" if r[\"status\"] == \"PASS\" else \"-\"\n            print(f\"  [{status_icon}] {r['test']}: {r['status']}\")\n            print(f\"      {r['detail']}\")\n\n        return self.results\n\n\nif __name__ == \"__main__\":\n    validator = DataDiodeValidator(\n        diode_tx_ip=\"10.30.1.100\",   # Operations zone TX\n        diode_rx_ip=\"172.16.1.100\",  # DMZ zone RX\n    )\n    validator.run_all_tests()\n```\n\n### Step 5: Validate Zone Architecture\n\nAfter implementation, validate the zone architecture by verifying that only authorized conduit traffic passes between zones and that all prohibited cross-zone paths are blocked.\n\n```bash\n# Validation test from Enterprise zone - should be blocked from reaching BPCS\nnmap -sT -p 502,44818,102,4840 10.20.0.0\u002F16 --reason\n# Expected: All ports filtered\u002Fclosed\n\n# Validation test from Operations zone - read-only Modbus should work\npython3 -c \"\nfrom pymodbus.client import ModbusTcpClient\nclient = ModbusTcpClient('10.20.1.10', port=502)\nclient.connect()\n# Read should succeed\nresult = client.read_holding_registers(0, 10, slave=1)\nprint(f'Read test: {\\\"PASS\\\" if not result.isError() else \\\"FAIL\\\"}')\n# Write should be blocked by firewall\nresult = client.write_register(0, 100, slave=1)\nprint(f'Write blocked: {\\\"PASS\\\" if result.isError() else \\\"FAIL - WRITE PERMITTED!\\\"}')\nclient.close()\n\"\n\n# Verify data diode blocks reverse traffic\nping -c 3 10.30.1.100  # From DMZ to OT - should timeout\n# Expected: 100% packet loss (hardware diode blocks ICMP)\n```\n\n## Key Concepts\n\n| Term | Definition |\n|------|------------|\n| Security Zone | A grouping of logical or physical assets that share common security requirements, as defined by IEC 62443-3-2 |\n| Conduit | A logical grouping of communication channels connecting two or more zones, subject to common security policies |\n| Security Level Target (SL-T) | The desired security level for a zone, ranging from SL 1 (casual violation) to SL 4 (state-sponsored attack) |\n| Data Diode | Hardware-enforced unidirectional network gateway that physically prevents data from flowing in the reverse direction |\n| Microsegmentation | Granular network segmentation at the device level, managing communication device-by-device based on roles and functions |\n| Deep Packet Inspection (DPI) | Firewall capability to inspect industrial protocol payloads (Modbus function codes, OPC UA service calls) beyond Layer 4 |\n| Defense in Depth | Layered security approach where multiple security controls protect assets at different levels of the architecture |\n\n## Tools & Systems\n\n- **Cisco ISA-3000**: Industrial security appliance providing OT-aware firewall, IPS, and VPN capabilities with Modbus, DNP3, and EtherNet\u002FIP inspection\n- **Fortinet FortiGate Rugged**: Ruggedized next-gen firewall with OT protocol support for industrial environments\n- **Palo Alto IoT\u002FOT Security**: Cloud-delivered OT security subscription providing device identification and protocol-aware policy enforcement\n- **Waterfall Security Solutions**: Hardware-enforced unidirectional security gateways (data diodes) for OT-to-IT data transfer\n- **Tofino Xenon**: Industrial security appliance providing deep packet inspection for Modbus, OPC, and EtherNet\u002FIP protocols\n\n## Common Scenarios\n\n### Scenario: Migrating Flat OT Network to Zone Architecture\n\n**Context**: A manufacturing plant operates all OT devices on a single VLAN (10.10.0.0\u002F16) with no segmentation between PLCs, HMIs, historians, and the corporate network. An IEC 62443 gap assessment identified this as a critical finding requiring zone implementation.\n\n**Approach**:\n1. Capture complete traffic baseline for 4 weeks using passive monitoring to identify all legitimate communication flows\n2. Classify all assets into Purdue levels and group into logical zones based on function and security requirements\n3. Design VLAN architecture with one VLAN per zone and inter-zone firewall rules based on observed legitimate traffic\n4. Deploy industrial firewalls at zone boundaries with initial \"monitor only\" mode (log but do not block)\n5. Analyze firewall logs for 2 weeks to identify any legitimate traffic that would be blocked\n6. Switch firewalls to enforcement mode during a scheduled maintenance window\n7. Validate that all process control communications function correctly post-segmentation\n8. Implement data diode between operations and DMZ for historian replication\n\n**Pitfalls**: Implementing zone firewalls without a complete traffic baseline will break unknown but legitimate communication paths. Scheduling zone cutover during production instead of maintenance windows risks process disruptions. Placing SIS controllers in the same zone as BPCS violates IEC 62443 safety system isolation requirements.\n\n## Output Format\n\n```\nIEC 62443 Zone Implementation Report\n=====================================\nFacility: [Name]\nImplementation Date: YYYY-MM-DD\nStandard: IEC 62443-3-2\u002F3-3\n\nZONE ARCHITECTURE:\n  Zone [ID]: [Name] (SL-T: [1-4])\n    Assets: [count]\n    Conduits: [list]\n    Controls: [firewall type, data diode, etc.]\n\nCONDUIT CONFIGURATION:\n  Conduit [ID]: [Zone A] \u003C-> [Zone B]\n    Protocols: [allowed protocols with direction]\n    Firewall Rules: [count allow \u002F count deny]\n    DPI Enabled: Yes\u002FNo\n\nVALIDATION RESULTS:\n  Cross-zone tests: [pass\u002Ffail count]\n  Prohibited path tests: [all blocked \u002F exceptions]\n  Protocol enforcement: [function code filtering verified]\n```\n",{"name":5,"tags":56,"author":58,"domain":50,"license":16,"version":59,"nist_csf":60,"subdomain":65,"description":66,"mitre_attack":67},[43,42,33,41,40,57,34],"network-segmentation","mahipal","1.0.0",[61,62,63,64],"PR.IR-01","DE.CM-01","ID.AM-05","GV.OC-02","ot-ics-security","Designs security zones and conduits for industrial control systems (IACS) per IEC 62443-3-2 — risk-based zone partitioning, Security Level target (SL-T) assignment, conduit controls, and firewall microsegmentation validated against the Purdue Reference Model. Use when designing OT network zones for a new facility, retrofitting zones into a flat OT network, or upgrading VLAN-only segmentation for IEC 62443-3-2 compliance.\n",[68,69,70,71,72],"T1078","T1190","T1059","T0816","T0836","main","54a798831d2266a3ca61ce68a7acb80b81160d57","skills\u002Fimplementing-iec-62443-security-zones",4425,"https:\u002F\u002Fgithub.com\u002Fmukul975\u002FAnthropic-Cybersecurity-Skills","https:\u002F\u002Fmahipal.engineer\u002FAnthropic-Cybersecurity-Skills\u002F","https:\u002F\u002Fgithub.com\u002Fmukul975","Mahipal.engineer","🔐 Cybersecurity | 💻 Dev | 📷 Street Photographer\r\n🎓 MSc | 📚 Research & AI Security","2026-08-31 12:32:44",{"source":9,"skillName":5,"commands":84,"prompt":94,"zipAvailable":95},[85,88,91],{"tool":86,"command":87},"npx","npx skills add mukul975\u002FAnthropic-Cybersecurity-Skills --skill implementing-iec-62443-security-zones",{"tool":89,"command":90},"bunx","bunx skills add mukul975\u002FAnthropic-Cybersecurity-Skills --skill implementing-iec-62443-security-zones",{"tool":92,"command":93},"pnpm","pnpm dlx skills add mukul975\u002FAnthropic-Cybersecurity-Skills --skill implementing-iec-62443-security-zones","安装技能，技能地址：https:\u002F\u002Fgithub.com\u002Fmukul975\u002FAnthropic-Cybersecurity-Skills\u002Fblob\u002Fmain\u002Fskills\u002Fimplementing-iec-62443-security-zones\u002FSKILL.md",true,[97,103,108,112],{"path":98,"resourceType":99,"resourceTypeDesc":100,"sizeBytes":101,"sourceHtmlUrl":102},"agents\u002Fopenai.yaml","REFERENCE","参考文档",166,"https:\u002F\u002Fgithub.com\u002Ffderuiter\u002FQRCraftly-web\u002Fblob\u002Fmain\u002F.agents\u002Fskills\u002Fto-questionnaire\u002Fagents\u002Fopenai.yaml",{"path":104,"resourceType":104,"resourceTypeDesc":105,"sizeBytes":106,"sourceHtmlUrl":107},"LICENSE","许可证",11255,"https:\u002F\u002Fgithub.com\u002Fmukul975\u002FAnthropic-Cybersecurity-Skills\u002Fblob\u002Fmain\u002Fskills\u002Fimplementing-iec-62443-security-zones\u002FLICENSE",{"path":109,"resourceType":99,"resourceTypeDesc":100,"sizeBytes":110,"sourceHtmlUrl":111},"references\u002Fapi-reference.md",1770,"https:\u002F\u002Fgithub.com\u002Fmukul975\u002FAnthropic-Cybersecurity-Skills\u002Fblob\u002Fmain\u002Fskills\u002Fimplementing-iec-62443-security-zones\u002Freferences\u002Fapi-reference.md",{"path":113,"resourceType":114,"resourceTypeDesc":115,"sizeBytes":116,"sourceHtmlUrl":117},"scripts\u002Fagent.py","SCRIPT","脚本",9009,"https:\u002F\u002Fgithub.com\u002Fmukul975\u002FAnthropic-Cybersecurity-Skills\u002Fblob\u002Fmain\u002Fskills\u002Fimplementing-iec-62443-security-zones\u002Fscripts\u002Fagent.py",[119,149,178,208,239,270],{"skillNo":120,"name":121,"nameZh":122,"description":123,"descriptionZh":124,"repositoryFullName":9,"ownerLogin":10,"ownerAvatarUrl":11,"ownerAccountNo":12,"ownerDisplayName":13,"repositoryNo":14,"starsCount":15,"licenseSpdxId":16,"licenseFileUrl":17,"sourceHtmlUrl":125,"categories":126,"keywords":131,"publishedAt":51},"01M6AGDM3HJXTKXX15ZZ0ZVCJ3","verifying-build-provenance-with-slsa-sigstore","SLSA 构建来源验证","Verifies artifact signatures and SLSA provenance using Sigstore's cosign (verify, verify-attestation, verify-blob-attestation) and slsa-verifier (verify-artifact), enforcing keyless OIDC builder identity and source repo against SLSA Build levels. Use in CI\u002FCD before deploying artifacts, when consuming third-party attestations, establishing a SLSA Build L3 pipeline, or confirming provenance during incident response or admission control.","使用 Sigstore 的 cosign（verify、verify-attestation、verify-blob-attestation）和 slsa-verifier（verify-artifact）验证工件签名和 SLSA 来源（provenance），强制校验 keyless OIDC 构建者身份和源仓库是否符合 SLSA Build 级别。适用于 CI\u002FCD 中部署工件前、消费第三方证明时、建立 SLSA Build L3 管道，或在事件响应或准入控制期间确认来源的场景。","https:\u002F\u002Fgithub.com\u002Fmukul975\u002FAnthropic-Cybersecurity-Skills\u002Fblob\u002Fmain\u002Fskills\u002Fverifying-build-provenance-with-slsa-sigstore\u002FSKILL.md",[127,128],{"categoryNo":21,"categoryName":22,"taxonomyType":23,"taxonomyTypeDesc":24},{"categoryNo":129,"categoryName":130,"taxonomyType":28,"taxonomyTypeDesc":29},"01M8C32Q37WAMK06SGMFC02VFP","软件供应链安全",[132,133,134,135,32,50,136,137,49,138,139,140,141,142,143,144,145,146,147,148],"sigstore","provenance","slsa","verifying build provenance with slsa sigstore","incident response","identity","code","artifacts","ci","supply-chain","pipeline","supply-chain-security","t1195","attestation","code-signing","cosign","keyless",{"skillNo":150,"name":151,"nameZh":152,"description":153,"descriptionZh":154,"repositoryFullName":9,"ownerLogin":10,"ownerAvatarUrl":11,"ownerAccountNo":12,"ownerDisplayName":13,"repositoryNo":14,"starsCount":15,"licenseSpdxId":16,"licenseFileUrl":17,"sourceHtmlUrl":155,"categories":156,"keywords":161,"publishedAt":51},"01M6AGDGBPWYVZ2F11GFKJ4HZ9","validating-tpm-measured-boot-attestation","TPM 测量启动验证","Verifies TPM 2.0 measured-boot integrity and remote attestation with tpm2-tools -- reading PCRs (tpm2_pcrread), replaying the boot event log, generating and checking signed quotes (tpm2_quote\u002Ftpm2_checkquote), and sealing secrets to a PCR policy. Use to confirm a system booted trusted firmware\u002Fkernel for Zero Trust device posture, detect boot-chain tampering via PCR drift, or build a golden-value baseline for fleet attestation.","使用 tpm2-tools 验证 TPM 2.0 测量启动（measured boot）的完整性和远程证明：读取 PCR（tpm2_pcrread）、重放启动事件日志、生成并检查签名报价（tpm2_quote\u002Ftpm2_checkquote），以及将机密封印（seal）到 PCR 策略。适用于确认系统已启动可信固件\u002F内核以实现零信任（Zero Trust）设备状态、通过 PCR 漂移检测启动链篡改，或构建黄金值基线用于机群（fleet）证明。","https:\u002F\u002Fgithub.com\u002Fmukul975\u002FAnthropic-Cybersecurity-Skills\u002Fblob\u002Fmain\u002Fskills\u002Fvalidating-tpm-measured-boot-attestation\u002FSKILL.md",[157,158],{"categoryNo":21,"categoryName":22,"taxonomyType":23,"taxonomyTypeDesc":24},{"categoryNo":159,"categoryName":160,"taxonomyType":28,"taxonomyTypeDesc":29},"01M8C89JJEXGGRGHS6XVXDA46K","终端安全加固",[162,145,163,164,32,165,50,49,166,167,168,169,170,171,172,173,174,175,176,177],"boot","TPM","validating tpm measured boot attestation","policy","verification","ZeRO","firmware","Tools","measured-boot","PCR","integrity","secrets","remote-attestation","tpm2-tools","integrity-verification","trusted-computing",{"skillNo":179,"name":180,"nameZh":181,"description":182,"descriptionZh":183,"repositoryFullName":9,"ownerLogin":10,"ownerAvatarUrl":11,"ownerAccountNo":12,"ownerDisplayName":13,"repositoryNo":14,"starsCount":15,"licenseSpdxId":16,"licenseFileUrl":17,"sourceHtmlUrl":184,"categories":185,"keywords":192,"publishedAt":51},"01M6AGDCW0Y4FXZ3362GT1941M","validating-backup-integrity-for-recovery","备份完整性验证","Validates backup integrity through cryptographic hash verification, automated restore testing, corruption detection, and recoverability checks to confirm backups are reliable for disaster recovery and ransomware response. Use before relying on backups for recovery, when building post-backup validation pipelines, auditing backup infrastructure for compliance, or checking immutable\u002Fair-gapped backups for silent corruption or tampering.","通过加密哈希验证、自动化恢复测试、损坏检测和可恢复性检查来验证备份完整性，确认备份对于灾难恢复和勒索软件响应是可靠的。适用于在依赖备份进行恢复之前、构建备份后验证管道、审计备份基础设施以满足合规要求，或检查不可变\u002Fair-gapped（气隙）备份是否存在静默损坏或篡改的场景。","https:\u002F\u002Fgithub.com\u002Fmukul975\u002FAnthropic-Cybersecurity-Skills\u002Fblob\u002Fmain\u002Fskills\u002Fvalidating-backup-integrity-for-recovery\u002FSKILL.md",[186,189],{"categoryNo":187,"categoryName":188,"taxonomyType":23,"taxonomyTypeDesc":24},"01M8BQGD4WETX0HM3SM9QKQ15B","SRE 工程师",{"categoryNo":190,"categoryName":191,"taxonomyType":28,"taxonomyTypeDesc":29},"01M8BSSTY86MWS6W5GDQWB1ADQ","备份与灾难恢复",[172,193,194,195,196,50,197,198,166,48,199,200,201,202,203,39,204,205,206,207],"backup","recovery","validating backup integrity for recovery","testing","infrastructure","validation","hash-verification","incident-response","ransomware","cryptocurrency","detection","t1490","immutable","disaster-recovery","restore-testing",{"skillNo":209,"name":210,"nameZh":211,"description":212,"descriptionZh":213,"repositoryFullName":9,"ownerLogin":10,"ownerAvatarUrl":11,"ownerAccountNo":12,"ownerDisplayName":13,"repositoryNo":14,"starsCount":15,"licenseSpdxId":16,"licenseFileUrl":17,"sourceHtmlUrl":214,"categories":215,"keywords":220,"publishedAt":51},"01M6AGD9GBG2KZ336AE763J3WH","triaging-windows-with-kape","KAPE Windows 取证收集","Runs KAPE (Kroll Artifact Parser and Extractor) to collect targeted forensic artifacts (registry hives, $MFT, event logs, prefetch, browser data) via Targets and parse them with Modules wrapping Eric Zimmerman's EZ Tools (PECmd, MFTECmd, RECmd). Use during early incident containment\u002Ftriage when full disk imaging is impractical but a defensible, parseable Windows artifact set is needed quickly, including at-scale remote collection.","运行 KAPE（Kroll Artifact Parser and Extractor），通过 Targets 收集目标取证工件（注册表配置单元、$MFT、事件日志、prefetch、浏览器数据），并使用封装 Eric Zimmerman 的 EZ Tools（PECmd、MFTECmd、RECmd）的 Modules 进行解析。适用于事件遏制\u002F分诊早期阶段——此时完整磁盘镜像不切实际，但需要快速获得可采信、可解析的 Windows 工件集，包括大规模远程收集。","https:\u002F\u002Fgithub.com\u002Fmukul975\u002FAnthropic-Cybersecurity-Skills\u002Fblob\u002Fmain\u002Fskills\u002Ftriaging-windows-with-kape\u002FSKILL.md",[216,217],{"categoryNo":21,"categoryName":22,"taxonomyType":23,"taxonomyTypeDesc":24},{"categoryNo":218,"categoryName":219,"taxonomyType":28,"taxonomyTypeDesc":29},"01M8C9JZH3GWXPJ6CQG5P7J48Y","数字取证与电子证据分析",[221,222,223,50,224,225,226,227,228,229,230,231,232,233,234,235,169,236,237,238],"windows","kape","triaging windows with kape","registry","browser","logs","windows-forensics","dfir","mft","mftecmd","data","prefetch","eric-zimmerman","digital-forensics","SET","collection","pecmd","artifact-collection",{"skillNo":240,"name":241,"nameZh":242,"description":243,"descriptionZh":244,"repositoryFullName":9,"ownerLogin":10,"ownerAvatarUrl":11,"ownerAccountNo":12,"ownerDisplayName":13,"repositoryNo":14,"starsCount":15,"licenseSpdxId":16,"licenseFileUrl":17,"sourceHtmlUrl":245,"categories":246,"keywords":251,"publishedAt":51},"01M6AGD5PW5J4EVZM958WD74ZQ","triaging-vulnerabilities-with-ssvc-framework","SSVC 漏洞优先级分诊","Triages and prioritizes vulnerabilities with CISA's Stakeholder-Specific Vulnerability Categorization (SSVC) decision tree, weighing exploitation status (via the CISA KEV catalog and FIRST EPSS API), technical impact, automatability, and mission prevalence to output Track\u002FTrack*\u002FAttend\u002FAct decisions. Use when prioritizing vulnerability scan results (OpenVAS, Nessus, Qualys) for remediation planning beyond raw CVSS scores.","使用 CISA 的 Stakeholder-Specific Vulnerability Categorization（SSVC，利益相关方特定漏洞分类）决策树对漏洞进行分诊和优先级排序，权衡利用状态（通过 CISA KEV 目录和 FIRST EPSS API）、技术影响、自动化程度和任务普遍性，输出 Track\u002FTrack*\u002FAttend\u002FAct 决策。适用于对漏洞扫描结果（OpenVAS、Nessus、Qualys）进行优先级排序以制定修复计划，而不局限于原始 CVSS 分数的场景。","https:\u002F\u002Fgithub.com\u002Fmukul975\u002FAnthropic-Cybersecurity-Skills\u002Fblob\u002Fmain\u002Fskills\u002Ftriaging-vulnerabilities-with-ssvc-framework\u002FSKILL.md",[247,250],{"categoryNo":248,"categoryName":249,"taxonomyType":28,"taxonomyTypeDesc":29},"01M8BQV98CYQ7TEW2D1MRQ00TE","安全公告与漏洞管理",{"categoryNo":21,"categoryName":22,"taxonomyType":23,"taxonomyTypeDesc":24},[252,253,254,50,255,256,257,258,259,260,261,262,263,264,37,265,266,267,268,269],"vulnerabilities","framework","triaging vulnerabilities with ssvc framework","status","planning","CISA","vulnerability-management","risk-management","nessus","qualys","openvas","cvss","remediation","vulnerability","api","prioritization","ssvc","decision-tree",{"skillNo":271,"name":272,"nameZh":273,"description":274,"descriptionZh":275,"repositoryFullName":9,"ownerLogin":10,"ownerAvatarUrl":11,"ownerAccountNo":12,"ownerDisplayName":13,"repositoryNo":14,"starsCount":15,"licenseSpdxId":16,"licenseFileUrl":17,"sourceHtmlUrl":276,"categories":277,"keywords":282,"publishedAt":51},"01M6AGD24TTQQM4CXG69E3B9TJ","triaging-security-incident","安全事件初步分诊","Performs initial triage of security incidents using the NIST SP 800-61r3 and SANS PICERL frameworks, classifying incident type, assigning priority by business impact, and routing to the appropriate response team. Use when a SIEM\u002FEDR alert needs human classification, concurrent alerts must be prioritized, or a user report or threat-intel IOC match requires initial incident categorization.","使用 NIST SP 800-61r3 和 SANS PICERL 框架对安全事件进行初步分诊，分类事件类型、按业务影响分配优先级，并路由到相应的响应团队。适用于 SIEM\u002FEDR 告警需要人工分类、并发告警必须确定优先级，或用户报告或威胁情报 IOC 匹配需要初步事件分类的场景。","https:\u002F\u002Fgithub.com\u002Fmukul975\u002FAnthropic-Cybersecurity-Skills\u002Fblob\u002Fmain\u002Fskills\u002Ftriaging-security-incident\u002FSKILL.md",[278,279],{"categoryNo":21,"categoryName":22,"taxonomyType":23,"taxonomyTypeDesc":24},{"categoryNo":280,"categoryName":281,"taxonomyType":28,"taxonomyTypeDesc":29},"01M8BTHYSJPJ500X64JJ5CH06D","安全事件响应与威胁狩猎",[32,283,50,284,285,286,287,288,289,290,291,39,292,204,293,294,295,296,297,298],"triaging security incident","siem","file","ioc","soc","NIST-800-61","NIST","severity","edr","execution","analysis","classification","severity-classification","incident-triage","SANS-PICERL","SOC-operations"]