AGENT SKILL

implementing-ics-firewall-with-tofino

Deploys and configures Tofino industrial firewalls (Belden/Hirschmann) to protect SCADA systems and PLCs, using deep packet inspection of OT protocols (Modbus, EtherNet/IP, OPC, S7comm) to enforce access control between ICS zones. Use when deploying zone-level firewall protection in front of PLCs/RTUs, enforcing IEC 62443 zone/conduit boundaries, or adding compensating controls for unpatchable legacy PLCs.

License 许可
Apache-2.0
最近更新
2026-08-31
Stars
★ 3.6w
Forks
4.4k

01 前言 Front Matter

name
implementing-ics-firewall-with-tofino
tags
[ "ot-security", "ics", "firewall", "tofino", "belden", "deep-packet-inspection", "network-security", "scada" ]
author
mahipal
domain
cybersecurity
license
Apache-2.0
version
1.0
nist_csf
[ "PR.IR-01", "DE.CM-01", "ID.AM-05", "GV.OC-02" ]
subdomain
ot-ics-security
description
Deploys and configures Tofino industrial firewalls (Belden/Hirschmann) to protect SCADA systems and PLCs, using deep packet inspection of OT protocols (Modbus, EtherNet/IP, OPC, S7comm) to enforce access control between ICS zones. Use when deploying zone-level firewall protection in front of PLCs/RTUs, enforcing IEC 62443 zone/conduit boundaries, or adding compensating controls for unpatchable legacy PLCs.
mitre_attack
[ "T1078", "T1190", "T1059", "T0816", "T0836" ]

02 资源文件 3

03 SKILL.md 正文

Implementing ICS Firewall with Tofino

When to Use

  • When deploying zone-level firewall protection directly in front of critical PLCs or RTUs
  • When requiring deep packet inspection of industrial protocols (Modbus, EtherNet/IP, OPC, S7comm)
  • When implementing IEC 62443 zone and conduit boundaries with protocol-aware enforcement
  • When protecting legacy PLCs that cannot be patched and need compensating controls
  • When segmenting control network zones without disrupting existing industrial communications

Do not use for enterprise IT firewall deployment, for perimeter firewall between IT and OT (use Palo Alto/Fortinet at the DMZ), or for environments using only IP-based protocols without OT-specific DPI needs.

Prerequisites

  • Tofino Xenon appliance or Tofino virtual appliance with appropriate license
  • Tofino Central Management Platform (CMP) for centralized policy management
  • Network topology map showing PLC/RTU placement and communication requirements
  • Baseline of OT protocol communications (Modbus function codes, EtherNet/IP CIP services)
  • Change management approval for inline deployment between network zones

Workflow

Step 1: Design Tofino Deployment Architecture

# Tofino ICS Firewall Deployment Architecture
# Zone-level protection using deep packet inspection

deployment_zones:
  zone_1_reactor_control:
    tofino_appliance: "TOFINO-XN-001"
    deployment_mode: "inline_bridge"
    protected_assets:
      - name: "PLC-REACTOR-01"
        ip: "10.10.1.10"
        vendor: "Siemens S7-1500"
        protocols: ["S7comm/102", "Profinet"]
      - name: "PLC-REACTOR-02"
        ip: "10.10.1.11"
        vendor: "Siemens S7-1500"
        protocols: ["S7comm/102", "Profinet"]
    authorized_communications:
      - source: "10.10.2.50"  # Engineering workstation
        dest: "10.10.1.0/24"
        protocols: ["S7comm"]
        access_type: "engineering"
      - source: "10.10.2.10"  # HMI server
        dest: "10.10.1.0/24"
        protocols: ["S7comm"]
        access_type: "operational"

  zone_2_packaging:
    tofino_appliance: "TOFINO-XN-002"
    deployment_mode: "inline_bridge"
    protected_assets:
      - name: "PLC-PACK-01"
        ip: "10.10.3.10"
        vendor: "Rockwell ControlLogix"
        protocols: ["EtherNet-IP/44818", "CIP"]
    authorized_communications:
      - source: "10.10.2.20"  # HMI
        dest: "10.10.3.0/24"
        protocols: ["EtherNet-IP"]
        access_type: "operational"

  zone_3_utilities:
    tofino_appliance: "TOFINO-XN-003"
    deployment_mode: "inline_bridge"
    protected_assets:
      - name: "RTU-BOILER-01"
        ip: "10.10.4.10"
        vendor: "Schneider M340"
        protocols: ["Modbus-TCP/502"]
    authorized_communications:
      - source: "10.10.2.30"  # SCADA server
        dest: "10.10.4.0/24"
        protocols: ["Modbus-TCP"]
        allowed_function_codes: [1, 2, 3, 4]  # Read only from SCADA

Step 2: Configure Deep Packet Inspection Rules

#!/usr/bin/env python3
"""Tofino ICS Firewall Rule Generator.

Generates Tofino firewall rules with deep packet inspection for
industrial protocols based on communication baseline analysis.
"""

import json
import sys
from datetime import datetime
from typing import Dict, List


class TofinoRuleGenerator:
    """Generates Tofino ICS firewall DPI rules."""

    def __init__(self):
        self.rules = []
        self.rule_id = 1000

    def add_modbus_rule(self, src: str, dst: str, allowed_funcs: List[int],
                        allowed_registers: List[dict] = None, description: str = ""):
        """Generate Modbus DPI rule."""
        func_names = {
            1: "read_coils", 2: "read_discrete_inputs",
            3: "read_holding_registers", 4: "read_input_registers",
            5: "write_single_coil", 6: "write_single_register",
            15: "write_multiple_coils", 16: "write_multiple_registers",
        }

        rule = {
            "rule_id": self.rule_id,
            "protocol": "Modbus-TCP",
            "action": "ALLOW",
            "source": src,
            "destination": dst,
            "port": 502,
            "dpi_policy": {
                "allowed_function_codes": [
                    {"code": fc, "name": func_names.get(fc, f"FC{fc}")}
                    for fc in allowed_funcs
                ],
                "blocked_function_codes": [
                    fc for fc in range(1, 128) if fc not in allowed_funcs
                ],
            },
            "description": description,
            "log": True,
        }

        if allowed_registers:
            rule["dpi_policy"]["allowed_register_ranges"] = allowed_registers

        self.rules.append(rule)
        self.rule_id += 1
        return rule

    def add_s7comm_rule(self, src: str, dst: str, allowed_operations: List[str],
                        description: str = ""):
        """Generate S7comm DPI rule."""
        operation_map = {
            "read": {"function": 0x04, "name": "Read Variable"},
            "write": {"function": 0x05, "name": "Write Variable"},
            "setup": {"function": 0xF0, "name": "Setup Communication"},
            "download": {"function": 0x1A, "name": "Request Download"},
            "upload": {"function": 0x1D, "name": "Start Upload"},
            "cpu_stop": {"function": 0x29, "name": "PLC Stop"},
            "cpu_start": {"function": 0x28, "name": "PI Service (Start)"},
        }

        rule = {
            "rule_id": self.rule_id,
            "protocol": "S7comm",
            "action": "ALLOW",
            "source": src,
            "destination": dst,
            "port": 102,
            "dpi_policy": {
                "allowed_operations": [
                    operation_map[op] for op in allowed_operations if op in operation_map
                ],
                "block_cpu_stop": "cpu_stop" not in allowed_operations,
                "block_program_download": "download" not in allowed_operations,
            },
            "description": description,
            "log": True,
        }

        self.rules.append(rule)
        self.rule_id += 1
        return rule

    def add_ethernet_ip_rule(self, src: str, dst: str, allowed_services: List[str],
                              description: str = ""):
        """Generate EtherNet/IP CIP DPI rule."""
        rule = {
            "rule_id": self.rule_id,
            "protocol": "EtherNet-IP",
            "action": "ALLOW",
            "source": src,
            "destination": dst,
            "port": 44818,
            "dpi_policy": {
                "allowed_cip_services": allowed_services,
                "block_firmware_flash": True,
                "block_program_download": "program_download" not in allowed_services,
            },
            "description": description,
            "log": True,
        }

        self.rules.append(rule)
        self.rule_id += 1
        return rule

    def add_default_deny(self):
        """Add default deny rule at the end."""
        self.rules.append({
            "rule_id": 9999,
            "protocol": "ANY",
            "action": "DENY",
            "source": "ANY",
            "destination": "ANY",
            "port": "ANY",
            "description": "Default deny - block all unmatched traffic",
            "log": True,
        })

    def generate_config(self) -> str:
        """Generate complete Tofino firewall configuration."""
        config = {
            "tofino_configuration": {
                "generated": datetime.now().isoformat(),
                "appliance_model": "Tofino Xenon",
                "firmware_version": "4.2",
                "mode": "inline_bridge",
                "failsafe": "fail_open",
                "rules": self.rules,
            }
        }
        return json.dumps(config, indent=2)

    def print_summary(self):
        """Print rule summary."""
        print(f"\n{'='*65}")
        print("TOFINO ICS FIREWALL RULE SUMMARY")
        print(f"{'='*65}")
        print(f"Generated: {datetime.now().isoformat()}")
        print(f"Total Rules: {len(self.rules)}")

        for rule in self.rules:
            action_icon = "+" if rule["action"] == "ALLOW" else "X"
            print(f"\n  [{action_icon}] Rule {rule['rule_id']}: {rule.get('description', '')}")
            print(f"      {rule['source']} -> {rule['destination']}:{rule['port']}")
            print(f"      Protocol: {rule['protocol']}")
            if "dpi_policy" in rule:
                dpi = rule["dpi_policy"]
                if "allowed_function_codes" in dpi:
                    funcs = [f["name"] for f in dpi["allowed_function_codes"]]
                    print(f"      DPI - Allowed Modbus FCs: {', '.join(funcs)}")
                if "allowed_operations" in dpi:
                    ops = [o["name"] for o in dpi["allowed_operations"]]
                    print(f"      DPI - Allowed S7 Ops: {', '.join(ops)}")


if __name__ == "__main__":
    gen = TofinoRuleGenerator()

    # SCADA server to Modbus RTUs: read-only
    gen.add_modbus_rule(
        src="10.10.2.30",
        dst="10.10.4.0/24",
        allowed_funcs=[1, 2, 3, 4],
        description="SCADA to utilities RTUs - read only",
    )

    # Engineering workstation to Siemens PLCs: full access
    gen.add_s7comm_rule(
        src="10.10.2.50",
        dst="10.10.1.0/24",
        allowed_operations=["read", "write", "setup", "download", "upload"],
        description="Engineering WS to reactor PLCs - full engineering access",
    )

    # HMI to Siemens PLCs: read + write only (no program download)
    gen.add_s7comm_rule(
        src="10.10.2.10",
        dst="10.10.1.0/24",
        allowed_operations=["read", "write", "setup"],
        description="HMI to reactor PLCs - operational access only",
    )

    # HMI to Rockwell PLCs: operational access
    gen.add_ethernet_ip_rule(
        src="10.10.2.20",
        dst="10.10.3.0/24",
        allowed_services=["read_tag", "write_tag", "get_attribute"],
        description="HMI to packaging PLCs - operational access",
    )

    gen.add_default_deny()
    gen.print_summary()

Key Concepts

Term Definition
Tofino Xenon Belden/Hirschmann industrial firewall appliance with deep packet inspection for OT protocols
Deep Packet Inspection (DPI) Examining message payload content beyond headers to enforce fine-grained rules on industrial protocol operations
Inline Bridge Mode Transparent deployment mode where the firewall sits between network segments without requiring IP changes
Fail-Open Safety mode where firewall passes all traffic if the appliance fails, maintaining process availability
Loadable Security Module (LSM) Tofino plugin module providing protocol-specific DPI for Modbus, EtherNet/IP, OPC, or other protocols
Central Management Platform (CMP) Tofino centralized management server for deploying and managing policies across multiple Tofino appliances

Output Format

TOFINO DEPLOYMENT REPORT
===========================
Date: YYYY-MM-DD
Appliances Deployed: [count]

PER-APPLIANCE SUMMARY:
  [Appliance ID]:
    Mode: Inline Bridge
    Failsafe: Fail-Open
    Protected Assets: [count]
    Rules: [count]
    DPI Protocols: [list]

RULE SUMMARY:
  Allow Rules: [count]
  Deny Rules: [count]
  DPI-Enforced Rules: [count]

MONITORING:
  Blocked Packets (24h): [count]
  DPI Violations (24h): [count]

04 同仓库更多 Skills

mukul975
mukul975/Anthropic-Cybersecurity-Skills

verifying-build-provenance-with-slsa-sigstore

Verifies artifact signatures and SLSA provenance using Sigstore's cosign (verify, verify-attestation, verify-blob-attestation) and slsa-verifier (verify-artifact), enforcing keyless OIDC builder identity and source repo against SLSA Build levels. Use in CI/CD before deploying artifacts, when consuming third-party attestations, establishing a SLSA Build L3 pipeline, or confirming provenance during incident response or admission control.

Skill与智能体开发
★ 3.6w
mukul975
mukul975/Anthropic-Cybersecurity-Skills

validating-tpm-measured-boot-attestation

Verifies TPM 2.0 measured-boot integrity and remote attestation with tpm2-tools -- reading PCRs (tpm2_pcrread), replaying the boot event log, generating and checking signed quotes (tpm2_quote/tpm2_checkquote), and sealing secrets to a PCR policy. Use to confirm a system booted trusted firmware/kernel for Zero Trust device posture, detect boot-chain tampering via PCR drift, or build a golden-value baseline for fleet attestation.

Skill与智能体开发
★ 3.6w
mukul975
mukul975/Anthropic-Cybersecurity-Skills

validating-backup-integrity-for-recovery

Validates backup integrity through cryptographic hash verification, automated restore testing, corruption detection, and recoverability checks to confirm backups are reliable for disaster recovery and ransomware response. Use before relying on backups for recovery, when building post-backup validation pipelines, auditing backup infrastructure for compliance, or checking immutable/air-gapped backups for silent corruption or tampering.

测试与质量Skill与智能体开发
★ 3.6w
mukul975
mukul975/Anthropic-Cybersecurity-Skills

triaging-windows-with-kape

Runs KAPE (Kroll Artifact Parser and Extractor) to collect targeted forensic artifacts (registry hives, $MFT, event logs, prefetch, browser data) via Targets and parse them with Modules wrapping Eric Zimmerman's EZ Tools (PECmd, MFTECmd, RECmd). Use during early incident containment/triage when full disk imaging is impractical but a defensible, parseable Windows artifact set is needed quickly, including at-scale remote collection.

Skill与智能体开发
★ 3.6w
mukul975
mukul975/Anthropic-Cybersecurity-Skills

triaging-vulnerabilities-with-ssvc-framework

Triages and prioritizes vulnerabilities with CISA's Stakeholder-Specific Vulnerability Categorization (SSVC) decision tree, weighing exploitation status (via the CISA KEV catalog and FIRST EPSS API), technical impact, automatability, and mission prevalence to output Track/Track*/Attend/Act decisions. Use when prioritizing vulnerability scan results (OpenVAS, Nessus, Qualys) for remediation planning beyond raw CVSS scores.

Skill与智能体开发
★ 3.6w
mukul975
mukul975/Anthropic-Cybersecurity-Skills

triaging-security-incident

Performs initial triage of security incidents using the NIST SP 800-61r3 and SANS PICERL frameworks, classifying incident type, assigning priority by business impact, and routing to the appropriate response team. Use when a SIEM/EDR alert needs human classification, concurrent alerts must be prioritized, or a user report or threat-intel IOC match requires initial incident categorization.

Skill与智能体开发
★ 3.6w